BELAR ELECTRONICS LABORATORY, INC. 119 LANCASTER AVENUE ● P.O. BOX 76 ● DEVON, PA 19333-0076 USA VOICE (610) 687-5550 ● FAX (610) 687-2686 ww
FMCS-1 Monitor BELAR ELECTRONICS LABORATORY, INC. Page 7 9. SEPARATION BARGRAPH SCREEN SCREEN DISPLAY DATA Left & Right Modulation: Peak Modula
FMCS-1 Monitor Page 8 FMCS-1 11. RF SPECTRUM SCREEN The RF spectrum screen displays the RF spectrum centered around the tuning frequency with freque
FMCS-1 Monitor BELAR ELECTRONICS LABORATORY, INC. Page 9 13. AUDIO SPECTRUM SCREEN The Audio spectrum screen displays the Audio spectrums from 0 to
FMCS-1 Monitor Page 10 FMCS-1 14. RDS BASIC DATA SCREEN The basic RDS data screen displays data encoded on the 57 kHz RDS subcarrier from the RDS de
FMCS-1 Monitor BELAR ELECTRONICS LABORATORY, INC. Page 11 15. ALARMS/RELAY SCREEN SCREEN SELECTABLE DATA To select a parameter click on the screen,
FMCS-1 Monitor Page 12 FMCS-1 16. POPUP MENUS Many of the FMCS-1 Parameters and Information are accessed using popup menus. To access the popup menu
FMCS-1 Monitor BELAR ELECTRONICS LABORATORY, INC. Page 13 16-2. COMPOSITE POPUP MENU Filter BW: Selects Composite filter bandwidth: Stereo + RDS (p
FMCS-1 Monitor Page 14 FMCS-1 16-4. RF SPECTRUM POPUP MENU Display Mode: The Display Mode affects how the spectrum data is presented, in Realtime mo
FMCS-1 Monitor BELAR ELECTRONICS LABORATORY, INC. Page 15 16-6. AUDIO SPECTRUM POPUP MENU Input Type: Selects a single or dual input spectrum. Inpu
FMCS-1 Monitor Page 16 FMCS-1 16-8. OUTPUT SETTINGS POPUP MENU The FMCS-1provides 8 channels of analog audio output, 8 channels of AES/EBU output, a
WARRANTY, FACTORY RECALIBRATION AND FACTORY SERVICE FOR ASSISTANCE: CONTACT YOUR BELAR SALES REPRESENTATIVE CUSTOMER SERVICE AT THE BELAR FACTO
FMCS-1 Monitor BELAR ELECTRONICS LABORATORY, INC. Page 17 16-10. NETWORK CONFIGURE POPUP MENU IP Address: DHCP must be disabled to enter a static I
FMCS-1 Monitor Page 18 FMCS-1 16-12. INFO SETTINGS POPUP MENU BOOT: Processor Boot Code Version and Date. MAIN: Processor Main Code Version and Date
FMCS-1 Monitor BELAR ELECTRONICS LABORATORY, INC. Page 19 17. SOFTWARE SETUP AND UNIT UPDATE INFORMATION The FMCS-1 maybe connected to a computer
BELAR ELECTRONICS LABORATORY, INC. 119 LANCASTER AVENUE P.O. BOX 76 DEVON, PA 19333 USA VOICE (610) 687-5550 ● FAX (610) 687-2686 www.be
Table of Contents 1. General Information ...
FMCS-1 Monitor BELAR ELECTRONICS LABORATORY, INC. Page 1 1. GENERAL INFORMATION Description The FMCS-1 provides a complete solution for the Analo
FMCS-1 Monitor Page 2 FMCS-1 2. FRONT PANEL The FMCS-1 front panel consists of a 640x240 pixel color LCD display, a rotary encoder with push switch
FMCS-1 Monitor BELAR ELECTRONICS LABORATORY, INC. Page 3 3. REAR PANEL High Level RF Inputs ...
FMCS-1 Monitor Page 4 FMCS-1 4. MAIN TUNING SCREEN SCREEN DISPLAY DATA Total Peak Indicator: Total Peak Modulation Pilot Presence Indicator: Pilot